Level 2 ASPs
Level 2 ASPs install overhead or underground service lines between the electrical wiring on a Connection Applicant’s premise and the electricity network. This includes connecting service lines to the network and making the connection live.
- Proactive discussions, engagement and insights from Level 2 Accredited Service Providers;
- Critical information updates; and
- Other useful and relevant information.
If you need further information or support, please email aspinfo@essentialenergy.com.au
Level 2 ASPs install overhead or underground service lines between the electrical wiring on a Connection Applicant’s premise and the electricity network. This includes connecting service lines to the network and making the connection live.
- Proactive discussions, engagement and insights from Level 2 Accredited Service Providers;
- Critical information updates; and
- Other useful and relevant information.
If you need further information or support, please email aspinfo@essentialenergy.com.au
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Bushfire rebate conclusion
What is Happening?
As per Briefing – Connections for Bushfire-Affected Customers, the two-year period to claim this reimbursement has closed.
Reimbursement will apply for any current connection applications but will not apply for any new jobs submitted after Wednesday, 6 April 2022.
Please submit any final claims by Wednesday, 6 April 2022.
What do you need to do?
- Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Introduction of new fees and upfront payment
What is Happening?
Essential Energy will be introducing fees for some Low Voltage Connection Applications. From 2 May 2022, new charges will be applied to certain services where we are required by Australian Energy Regulator (AER) to charge for these services. These charges include:
- Fees for connection enquiries based on the estimated effort to complete (noting not all enquiries will be charged a fee)
- Additional fees to some connection applications where detailed engineering assessments (1% of applications) or power quality studies are required (0.1% of all applications a year)
- Incomplete information fee applied to applications that are submitted without the required information or attachments/supporting information included.
- We are continuing the transition to upfront payments of high volume and low value ANS charges.
The fees can be found in the table below:
The above table of Ancillary Network Service and Amounts are as per the Price Schedule for Ancillary Network Services 1 July 2021. These Network Service changes will move to upfront payment via the secure online payment gateway.
“User Pays” Principle
These fees cover the costs of services that we already provide and are expected to charge for under our agreement with the Australian Energy Regulator (AER).
Under the Regulatory Framework, we need to recover those costs from the specific customers requiring the service.
What do you need to do?
- Accredited Service Providers, Authorised Persons and Electrical Contractors should consider pricing changes when preparing quotations for customers regarding future work.
- Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Reimbursement for reconnection – flood impacted customers North Coast
What is Happening?
Essential Energy continues to work hand in hand with many ASPs across the flood impacted North Coast, repairing the significantly damaged electricity network and reconnecting power for customers whose properties were inundated with flood water.
The process for customers for reconnection involves three-steps.
- Arrange for either a licensed electrician or Level 2 Authorised Service Provider (ASP) to inspect property to make sure it is safe.
- When the inspection is completed, the electrician will log a Certificate of Compliance for Electrical Work (CCEW) and provide the customer with a CCEW reference number.
- Call Essential Energy on 13 20 80 to have your power restored.
Where a customer engaged Level 2 ASP performs the reconnection process, they charge the customer for this service. As Essential Energy is waiving the reconnection fee where we perform this service, and to ensure that all customers are treated equally, Essential Energy has offered to reimburse customers who are reconnected by an ASP up to $350 for that reconnection.
Given the trying conditions our customers are facing, Essential Energy will now streamline this process and pay Level 2 ASPs directly for reconnection on behalf of a flood-affected customer once they have completed the reconnection.
How do I arrange payment for customer reconnection work?
Once inspection and the necessary repairs to a premises’ switchboard and internal wiring has occurred, a CCEW provided and reconnection completed by a Level 2 ASP, the following process can be followed for payment:
Submit to Essential Energy via emailing connection.enquiries@essentialenergy.com.au
- An itemised invoice for the reconnection process.
- Copy of the Certificate of Compliance for Electrical Work.
- Copy of the Notice of Service Works (NOSW) when reconnection at Essential Energy service main.
- Completed new vendor information form.
This process needs to be followed for every individual NMI. There will be one reimbursement for each NMI.
For clarity there are circumstances where ASPs will not receive a payment for each individual unit/complex as there is only 1 NMI connection to Essential Energy network for these sites. Examples of where there is only one reconnection to the network for the below and 1 claim for reimbursement up to $350 are:
- Residential unit complexes
- Caravan parks with private metering
- Commercial complexes with multiple units
- Industrial complexes with multiple units
It is important to note that Essential Energy is funding the cost of reconnection up to $350, and any repairs to the customer’s electrical installation will not be reimbursed. Essential Energy has processes in place to ensure that claims for reconnection costs are not paid where Essential Energy has performed the reconnection.
The Customer Contact Centre will provide a Case Number by return email. Please keep this number as your reference.
The reimbursement will be provided by direct credit to your nominated bank account.
What do you need to do?
- Communicate this information to relevant members of your organisation.
- View this communication via Essential Engagement.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Procedure for bypassing flood-impacted meters and Frequency Injection Relays
Procedure for bypassing flood-impacted meters and Frequency Injection Relays
All meters and Frequency Injection Relays (FIRs) that have been submerged in water must be bypassed prior to re-energisation. This includes General Supply, Controlled Load Meters and Controlled Load Supply.
Please follow the procedure below to safely bypass meters and Frequency Injection Relays (FIRs) that have been impacted by the 2022 NSW floods. If a situation arises where you are unsure how you should proceed, stop, and call Essential Energy for assistance (see Essential Energy contacts listed on page 4).
Before commencing a bypass
Safety – At all times consider your own and the customer’s safety when bypassing meters. Ensure you have isolated all incoming supplies – even if the network is de-energised – and follow your own safety management systems and safe work methods. No electrical equipment should be assumed to be de-energised after disconnection or isolation. ALWAYS TEST PRIOR TO TOUCHING.
Types of meters – This guide applies to types 4, 5 & 6, whole current meters, and FIRs only. Current Transformer (CT) metering is excluded. Please contact Essential Energy for CT metering.
Assessing the situation – There are many different meter wiring configurations. Carefully check wiring before disconnecting meters. Ensure that you understand the wiring configuration. If you are unsure, call the Essential Energy contacts listed on page 4 to assist you.
A fuse or circuit breaker must never be bypassed. If an SPD or MPD has been damaged, it must be replaced before the meter can be bypassed and the installation re-energised. Do not use solid service fuse elements when reconnecting customers at the SPD/MPD. Essential Energy service mains are not fused at the pole top.
Meter Neutrals - In some installations you may find the main neutral terminates in the meter terminal and there is no Service Neutral Link. This neutral may daisy-chain to other meters, or there may be two or more neutral cables joined together in a meter terminal to supply a neutral to other meters, FIRs or timeclocks. The approved methods noted below can be used to join two or more neutrals together.
Neutral integrity – An open circuit in a neutral can lead to electrocution. If you are not sure of what you need to do, call the contacts listed on page 4 and ask for assistance.
IMPORTANT: Solar systems must be completely isolated if any component has been submerged or damaged. Care must be taken when isolating at the DC isolators, which may still be live, and isolation taken at the rooftop isolator first.
Use one of the following methods to bypass a meter
Method 1 – Insulated 2 screw connector may be used to join 2 or 3 cables together to get domestic and hot water working if there is room behind the board/panel. These will accommodate 2 x 35mm² cables and will not damage the cable as much as an HSC.
Method 2 – House Service Connector (HSC). In situations where the cables cannot be moved into the same terminal and you do not have any insulated 2 screw connectors, a HSC can be used to connect the cable behind the meter panel if there is room.
Method 3 – 4-way underground connector may be used to join 3 or 4 cables together to restore domestic and hot water supply if there is enough room behind the board/panel.
Bypassing Frequency Injection Relays (FIRs)
Remove 4mm or 6mm line side active from 40A single phase relay switch and load side active and twist together and connect with suitably rated single screw BP connector rated at least 20Amps. Put both lower and upper covers back on receiver so no wiring is exposed.
Normal wiring
Bypassed
Advanced multi-element meters
Most retailer-owned meters have more than one element available and may measure general rate, hot water, and solar export in the same meter. If you are unsure of the wiring configuration, do not bypass and call for assistance.
DO NOT USE:
- Line taps and tape. A line tap must not be used to join cables to bypass a meter.
- An IPC used for OH connections must not be used to join cables to bypass a meter.
Labelling switch boards
After bypassing meters and testing the premises, please label the meter and FIR ‘Bypassed’. Isolate and remove load side of CB/RCBO/fuse, install a connector and danger tag or tape any isolated circuits as shown below.
Recording bypassed meters and FIRs
Please record bypass information to ensure Essential Energy has the necessary information to arrange meter and FIR replacement. Once bypasses have been completed and the premises has been thoroughly checked and tested as safe to be energised as per normal procedures:
- Submit a CCEW via Essential Energy’s Secure Web Form (SWF) portal.
-
For consistency and clarity, in the Switchboard Particulars field make the following notes:
- For sites with meters only note ‘ALL METERS BYPASSED’
- For sites with meters and an FIR note ‘ALL METERs AND FIR BYPASSED’
Re-energisation by Level 2 ASPs following meter and FIR bypasses
When re-energising a premises with flood-impacted meters and FIRs:
- Ensure that meters and FIRs have been bypassed in accordance with these instructions.
- Confirm that a CCEW has been submitted and the customer’s electrical system has been thoroughly checked and tested as safe to be energised.
-
Submit a Notification of Service Work (NOSW) through SWF. For consistency and clarity, in the ‘Comments’ field in Section E make the following note:
- For sites with meters only note ‘ALL METERS BYPASSED’
- For sites with meters and an FIR note ‘ALL METERs AND FIR BYPASSED’
Essential Energy contacts
Please contact Essential Energy contacts for assistance, CT metering and FIR enquiries
- Lismore Hub - Rob Nash, 0437 927 163
- Ballina/Coraki Hub – Billy Holm, 0427 441 556
- Woodburn Hub – Mark Williams, 0408 639 488
- North Coast Regional Coordinator – Darren Butler, 0427 414 068
- Network Assurance Manager – Kevin Miller, 0407 784 701
- Essential Energy General Enquiries – 13 23 91 https://www.essentialenergy.com.au/our-network/floods/flood-reconnecting
What do you need to do?
- Review the above information and refer to the ASP & Electrical Contractor Briefing.
- Communicate this information to relevant members of your organisation.
- View this communication via Essential Engagement.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Reminder: Ancillary Network Services Fee Changes (Connection Offers)
What is Happening?
Essential Energy is changing the fees we charge for some Low Voltage Basic Connection Applications. We are providing six weeks’ notice of our first fee change to allow you time to prepare.
Basic Connection Application fee
From 14 March 2022, $123.38 (exc GST) will be charged per offer where a technical review is required.
This will ensure fee consistency for all Basic Connection Offers requiring technical review and recover the cost of assessing these applications from those requiring the work.
How will I know if I am going to be charged?
Basic connections involve minimal or no augmentation of the distribution network and are within the limits outlined below:
Basic Low Voltage Connection limits Connection Request Load Type Voltage Zone Usage Type New/modify Single Phase Less than 100 Amps Urban Domestic New/modify Multi Phase Less than 63 Amps/Phase Urban Domestic New Single Phase Less than 100 Amps
with Embedded Generation
(<=10KW and export limit <=5KW)Urban Domestic New Multi Phase Less than 63 Amps
with Embedded Generation
(<=10KW and export limit <=5KW)Urban Domestic Addition of New
Embedded Generation<=10KW and export limit <=5KW Urban Domestic Addition of New
Embedded Generation<=5KW and export limit <=3KW Rural Domestic A technical review is required when the proposed connection:
- exceeds these limits, and / or
- involves electricity generation (e.g., solar, wind, hydropower) to enable export to the electricity network.
A common application type impacted by this change is a new solar connection application. Please note that customers who include a note in their application that they are willing to voluntarily limit their solar export to 5kW (Urban) or 3kW (Rural) will not incur the fee.
Additional information can be found in our Connecting to the Network Information Pack.
Complex Connection Application fee
Complex Connection Applications can occasionally require a detailed assessment by a Connections Planning Engineer. Later this year, we will introduce a fee to recover the cost of any complex connection application that requires a detailed assessment by a Connections Planning Engineer. We will provide more information prior to this fee introduction.
What do you need to do
- Accredited Service Providers, Authorised Persons, Electrical Contractors, Solar Retailers and Solar Installers should consider pricing changes when preparing quotations or estimates for customers regarding future connection applications to be submitted on or after 14 March 2022.
- Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Reconnecting flood-affected customers
What is happening?
When reconnecting flood-affected customer premises, please follow the steps below to ensure safe and efficient power supply restoration:
1. Immediately after a successful safety and compliance inspection by a qualified electrical contractor, log a Certificate Compliance Electrical Work (CCEW) via Essential Energy’s Secure Web Forms (SWF) and leave a copy with your customer.
2. A Level 2 ASP must submit a NOSW immediately after reconnecting power to a premises (this will avoid our crews having to re-visit these premises).
3. A Level 2 ASP authorised person can perform the below:
- Class 2A – Reconnect at the connection point only
- Class 2B – Replace the Service Protection Device (SPD) and reenergise customers isolated at the switchboard
- Class 2C – Replace the Service Protection Device (SPD), reenergise customers isolated at the switchboard and reconnect at the connection point and point of common coupling
- Class 2D – can only reenergise as the Service Protection Device (SPD) / Meter Protection Device (MPD)
4. When submitting the NOSW, please make sure that the below fields are entered:
- NMI
- Address
- Postcode
- Connection Application number use 99999 (this will avoid submitting an LV Connection Application).
- Comments field add “CCEW confirmed before reenergised after flooded event”.
5. Flood affected areas will not be charged for submission of CCEW’s and NOSW’s during the flood recovery.
6. Essential Energy will reimburse customers up to $350 who use an ASP to cover the cost of safe reconnection. This reimbursement does not cover costs relating to the safety inspection or repair of damage to a customer’s own electrical equipment.
This advice has also been shared with our customers to help clarify their post-flood reconnection process.
What do you need to do?
1. Review the above and Essential Energy’s website at https://www.essentialenergy.com.au/our-network/floods/flood-reconnecting for more information.
2. Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Help us protect cyber security and our network following Russian invasion of Ukraine
What is Happening?
As you will be aware, the Australian Cyber Security Centre (ACSC) has issued an urgent alert advising all Australian organisations to heighten their cyber security as a result of the Russian invasion of the Ukraine.
Essential Energy’s technology teams are on high alert. We’ve increased monitoring of all our systems and gateways and are currently reviewing all internet-facing assets.
This includes reviewing and enhancing risk detection, mitigation, response measures and ensuring that logging and detection systems are fully updated and functioning.
As a valued partner, we trust in your vigilance and ask for early warning of any compromise of your systems that may impact Essential Energy. Your co-operation will be critical in helping us protect our assets and ensuring a safe and reliable power supply for our customers.
To report a compromised system or for further information please contact Essential Energy on 13 23 91.
What do you need to do?
- Communicate this information to relevant members of your organisation.
- View this communication via Essential Engagement.
Further Information
If you need further information, please contact Essential Energy on 13 23 91.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Help us streamline your access to our new connection’s enquiry and application portal
What is happening?
Essential Energy is working to improve our end-to-end connections process, progressively automating many previously manual processes through our new Connections Portal. To enable you to pre-register for access to the new Essential Connections Portal, we need to ensure that your contact information is up to date.
What is the Essential Connections Portal?
- The portal will simplify submitting connection information to Essential Energy and ensure that: information only needs to be submitted once
- current and historic jobs are accessible in one system
- requests can be submitted electronically (using different device types)
- notifications are automated, and
- users can easily ‘self-serve’ accurate information.
Eventually these improvements will cover Low Voltage (LV) and High Voltage (HV) Enquiries, Applications, Works Management, Testing and Quality Assurance processes.
When will the portal be released?
Release 1: LV Connection Enquiry and Applications
When: Expected to be released in late April or early May 2022
As the project progresses, we will keep you updated and share information on further enhancements.
What you can expect from us:
In the coming weeks, we will contact ASPs or ECs whose key contact information appears incomplete or who have replicated data in our systems to clarify:
- First/last name
- Contact details
- Current company name
- A unique email address (more than one email will be required if working for more than one company)
- Details of any administration staff who require portal access.
What do you need to do?
Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Ancillary Network Services Fee Changes (Connection Offers)
What is Happening?
Essential Energy is changing the fees we charge for some Low Voltage Basic Connection Applications. We are providing six weeks’ notice of our first fee change to allow you time to prepare.
Basic Connection Application fee
From 14 March 2022, $123.38 (exc GST) will be charged per offer where a technical review is required.
This will ensure fee consistency for all Basic Connection Offers requiring technical review and recover the cost of assessing these applications from those requiring the work.
How will I know if I am going to be charged?
Basic connections involve minimal or no augmentation of the distribution network and are within the limits outlined below:
Basic Low Voltage Connection limits Connection Request Load Type Voltage Zone Usage Type New/modify Single Phase Less than 100 Amps Urban Domestic New/modify Multi Phase Less than 63 Amps/Phase Urban Domestic New Single Phase Less than 100 Amps
with Embedded Generation
(<=10KW and export limit <=5KW)Urban Domestic New Multi Phase Less than 63 Amps
with Embedded Generation
(<=10KW and export limit <=5KW)Urban Domestic Addition of New
Embedded Generation<=10KW and export limit <=5KW Urban Domestic Addition of New
Embedded Generation<=5KW and export limit <=3KW Rural Domestic A technical review is required when the proposed connection:
- exceeds these limits, and / or
- involves electricity generation (e.g., solar, wind, hydropower) to enable export to the electricity network.
A common application type impacted by this change is a new solar connection application. Please note that customers who include a note in their application that they are willing to voluntarily limit their solar export to 5kW (Urban) or 3kW (Rural) will not incur the fee.
Additional information can be found in our Connecting to the Network Information Pack.
Complex Connection Application fee
Complex Connection Applications can occasionally require a detailed assessment by a Connections Planning Engineer. Later this year, we will introduce a fee to recover the cost of any complex connection application that requires a detailed assessment by a Connections Planning Engineer. We will provide more information prior to this fee introduction.
What do you need to do
- Accredited Service Providers, Authorised Persons, Electrical Contractors, Solar Retailers and Solar Installers should consider pricing changes when preparing quotations or estimates for customers regarding future connection applications to be submitted on or after 14 March 2022.
- Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
-
You cannot leave comment in this blogpost unless you are a part of the project panel.
Rejected Connection Applications
Background
Currently, around 20% of Connection Applications are rejected due to missing or incorrect information in the Connection Point / Pole / Substation Number field.
To help you submit correct applications, our recently released Network Information Portal provides a significant amount of information about Essential Energy’s network, including the asset numbers for all poles and substations in a Geographic Information System (GIS) mapping format.
The Network Information Portal is accessible on all devices. By typing in the address (or a nearby address), you can easily find the required connection point asset number.
What do you need to do?
- Watch a demonstration video and visit Network Information Portal via Essential Energy's Website and start exploring our network.
- Communicate this information to relevant members of your organisation.
Further Information
If you need further information, please email aspinfo@essentialenergy.com.au.
Who's Listening
-
Phone 02 6933 5956 Email hamish.wheatley@essentialenergy.com.au